  "id": "limits:icnirp-2020-sar-whole-body",
  "collection": "limits",
  "slug": "icnirp-whole-body-sar-limit",
  "name": "ICNIRP 2020 whole-body average SAR basic restriction",
  "summary": "0.08 W/kg for the general public and 0.4 W/kg occupational — the thermal basis from which every RF reference level is derived.",
  "status": "verified",
  "lastVerified": "2026-08-12",
  "data": {
    "standardId": "icnirp-2020",
    "population": "general-public",
    "quantity": "specific-absorption-rate",
    "band": {
      "minHz": 100000,
      "maxHz": 300000000000,
      "label": "100 kHz–300 GHz"
    },
    "averagingSeconds": 1800,
    "value": {
      "quantity": "specific-absorption-rate",
      "unit": "W/kg",
      "value": 0.08,
      "basis": "guideline",
      "note": "Occupational whole-body restriction is 0.4 W/kg; the public value applies a further factor of 5.",
      "sourceIds": [
        "icnirp-2020"
      ]
    }
  },
  "sources": [
    {
      "id": "icnirp-2020",
      "title": "Guidelines for Limiting Exposure to Electromagnetic Fields (100 kHz to 300 GHz)",
      "publisher": "International Commission on Non-Ionizing Radiation Protection",
      "url": "https://www.icnirp.org/en/publications/article/rf-guidelines-2020.html",
      "year": 2020,
      "kind": "guideline",
      "retrieved": "2026-08-12"
    }
  ],