  "id": "limits:sc6-public-6-15ghz",
  "collection": "limits",
  "slug": "safety-code-6-public-6-15-ghz",
  "name": "Safety Code 6 uncontrolled reference level, 6–15 GHz",
  "summary": "10 W/m² (61.4 V/m) averaged over 6 minutes — the flat plateau above 6 GHz, identical to the ICNIRP figure.",
  "status": "verified",
  "lastVerified": "2026-08-12",
  "data": {
    "standardId": "hc-safety-code-6",
    "population": "general-public",
    "quantity": "power-density",
    "band": {
      "minHz": 6000000000,
      "maxHz": 15000000000,
      "label": "6000–15,000 MHz"
    },
    "averagingSeconds": 360,
    "value": {
      "quantity": "power-density",
      "unit": "µW/m²",
      "value": 10000000,
      "basis": "guideline",
      "note": "Safety Code 6 (2015) Table 5 lists E = 61.4 V/m, H = 0.163 A/m and S = 10 W/m² for uncontrolled environments in this band; the controlled-environment plateau is 50 W/m².",
      "sourceIds": [
        "hc-safety-code-6",
        "hc-safety-code-6-pdf"
      ]
    }
  },
  "sources": [
    {
      "id": "hc-safety-code-6",
      "title": "Limits of Human Exposure to Radiofrequency Electromagnetic Energy in the Frequency Range from 3 kHz to 300 GHz (Safety Code 6)",
      "publisher": "Health Canada",
      "url": "https://www.canada.ca/en/health-canada/services/publications/health-risks-safety/limits-human-exposure-radiofrequency-electromagnetic-energy-range-3-300.html",
      "year": 2015,
      "kind": "guideline",
      "retrieved": "2026-08-12"
    },
    {
      "id": "hc-safety-code-6-pdf",
      "title": "Safety Code 6 (2015), H129-48/2015E-PDF — official PDF edition",
      "publisher": "Government of Canada Publications",
      "url": "https://publications.gc.ca/collections/collection_2016/sc-hc/H129-48-2015-eng.pdf",
      "year": 2015,
      "kind": "guideline",
      "retrieved": "2026-08-12"
    }
  ],
  "links": {