# Poland public limit, 10–400 MHz

> 28 V/m and 2 W/m² in places accessible to the public — up from the 7 V/m that applied before 1 January 2020.

- Canonical URL: https://emfbase.com/limits/poland-public-limit-10-400-mhz
- Collection: Exposure limits
- Record id: `limits:poland-public-10-400mhz`
- Status: verified
- Last verified: 2026-08-12
- JSON: https://emfbase.com/api/limits/poland-public-limit-10-400-mhz

## Key values

- **Limit value:** 28 V/m — Regulatory value — legally enforceable — Annex, Table 2, row 9: E = 28 V/m, H = 0.073 A/m, S = 2 W/m². Values apply to fixed power and radiocommunication networks, not to portable devices or appliances used in dwellings. [poland-mz-2019-2448]
- **Quantity:** electric field strength
- **Frequency band:** 10–400 MHz
- **Population:** general public
- **Set by:** Poland environmental EMF limits (Dz.U. 2019 poz. 2448) (Regulation of 17 December 2019, in force 1 January 2020)
- **Kind:** Regulatory — legally enforceable

## Related records

- [Poland environmental EMF limits (Dz.U. 2019 poz. 2448)](https://emfbase.com/standards/poland-environmental-emf-limits-2019): Poland replaced its 7 V/m environmental RF limit with the EU/ICNIRP reference levels on 1 January 2020, while keeping a stricter 1000 V/m 50 Hz electric-field value for land zoned for housing.

## Sources

- `poland-mz-2019-2448` Minister Zdrowia (Poland), Dziennik Ustaw (2019). *Rozporządzenie Ministra Zdrowia z dnia 17 grudnia 2019 r. w sprawie dopuszczalnych poziomów pól elektromagnetycznych w środowisku (Dz.U. 2019 poz. 2448)*. https://eli.gov.pl/eli/DU/2019/2448/ogl — regulation, link checked 2026-08-12
- `poland-5g-limits` Ministerstwo Cyfryzacji (Poland), gov.pl. *Dopuszczalne wartości pola elektromagnetycznego w Polsce — harmonizacja z zaleceniem Rady od 1 stycznia 2020 r.*. https://www.gov.pl/web/5g/dopuszczalne-wartosci-pola-elektromagnetycznego-w-polsce — government, link checked 2026-08-12

Data licence: CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Dataset version 2026.08.1. Retrieved from EMFBase, https://emfbase.com.

This record is reference data, not medical or legal advice. Regulatory limits, scientific guidelines and precautionary values are labelled separately and answer different questions.