# Swiss installation limit value for mobile phone antennas

> 4–6 V/m at places of sensitive use depending on band — about 100 times lower in power density than ICNIRP's reference level.

- Canonical URL: https://emfbase.com/limits/swiss-installation-limit-mobile-antennas
- Collection: Exposure limits
- Record id: `limits:ch-onir-installation-mobile`
- Status: verified
- Last verified: 2026-08-12
- JSON: https://emfbase.com/api/limits/swiss-installation-limit-mobile-antennas

## Key values

- **Limit value:** 4–6 V/m — Regulatory value — legally enforceable — 4 V/m for installations operating below ~900 MHz, 6 V/m above ~1.8 GHz, 5 V/m for mixed-band installations. 6 V/m ≈ 95,500 µW/m² via S = E²/377. [ch-onir]
- **Quantity:** electric field strength
- **Frequency band:** mobile service bands
- **Population:** sensitive
- **Set by:** Swiss ONIR / NISV installation limit values (2000, as amended)
- **Kind:** Regulatory — legally enforceable

## Sources

- `ch-onir` Swiss Confederation (2000). *Ordinance relating to Protection from Non-Ionising Radiation (ONIR / NISV, SR 814.710)*. https://www.fedlex.admin.ch/eli/cc/2000/38/en — regulation, link checked 2026-08-12
- `sbm-2024` Institut für Baubiologie + Nachhaltigkeit (IBN) (2024). *Building Biology Evaluation Guidelines for Sleeping Areas (SBM-2024)*. https://buildingbiology.com/site/downloads/SBM-2024_EVALUATION_GUIDELINES_EN.pdf — ngo, link checked 2026-08-12

Data licence: CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Dataset version 2026.08.1. Retrieved from EMFBase, https://emfbase.com.