ICNIRP's two-tier structure: basic restrictions are the dosimetric limits that matter biologically; reference levels are the externally measurable proxies derived from them.

regulation

Last verified 12 August 2026.

Category
regulation

Definition

A basic restriction limits an internal quantity such as SAR or induced electric field, which cannot be measured in a living person. A reference level limits an external quantity such as power density or magnetic flux density, and is derived conservatively so that compliance with it guarantees compliance with the basic restriction. Exceeding a reference level is therefore not automatically a breach of the basic restriction — it triggers a more detailed assessment.

Sources

  1. icnirp-2020 Guidelines for Limiting Exposure to Electromagnetic Fields (100 kHz to 300 GHz) International Commission on Non-Ionizing Radiation Protection, 2020. guideline, link checked 2026-08-12.