WOREMOR WM-HG03 stainless steel gauze
Fine stainless steel gauze with 0.3 mm mesh declared at 55 dB at 1 GHz and a square resistance of 0.03 Ω, which makes it groundable so it also controls low-frequency electric fields.
Last verified 12 August 2026.
Also searched as: WM-HG03, stainless steel shielding mesh, EMF gauze
- Manufacturer
- WOREMOR
- Model
- WM-HG03
- Material class
- Metal mesh and expanded-metal screen
- Fields addressed
- radiofrequency, elf electric
- Grounding required
- Yes — ungrounded installation can make things worse
- Thickness
- 0.16 mm
- Surface resistance
- 0.03 Ω square resistance
Declared attenuation
Each figure is the manufacturer's declaration for the frequency and the layer or coat count named next to it. The percentage is computed from the dB value, not quoted separately.
- 1 GHz, single layer, flat sample
- 55 dB — removes 100.000% of the incident power density (1 part in 316,228 gets through)
Test method
Manufacturer-declared at 1 GHz, measured to ASTM D4935-10 or IEEE Std 299-2006; WOREMOR publishes a screening report for the material. Fire classification A1 to DIN 4102:1994.
Construction
Woven V4A stainless steel, 0.3 mm mesh width, 0.08 mm wire, 54% open area, 200 g/m², 90 cm wide.
Typical application
- Drywall construction
- Roof areas and under plaster
- Loose-laid under floor coverings
- Insect screens
What the figure does not cover
- Mesh attenuation falls as wavelength approaches the aperture size, so the 1 GHz figure does not carry to mmWave frequencies
- Elements must overlap by at least 5 cm and be bonded together; an unbonded overlap behaves as a slot and leaks
- Grounding is required to shield low-frequency electric fields, and the gauze is highly conductive, so it must be bonded correctly to avoid becoming a hazard near wiring
- The declared figure is for a flat sample: the installed result is set by the least-shielded path, usually a window or a penetration
What these figures are
Every attenuation value on this page is the manufacturer's own declaration for a flat sample in a test fixture, reproduced so that products can be compared on the same terms. It is not a regulatory limit, not an independent test, and not a prediction of what a meter will read after installation — an installed shield is set by its weakest path, so the only figure that describes a room is a before-and-after measurement of that room.
Where to buy
EMR Shielding Solutions is a related company of WebKMS, which publishes EMFBase, and sells this product. The link is a stockist listing only: every figure on this page comes from the manufacturer's own documentation, and no specification, limitation or citation depends on it.
Related records
- Metal mesh and expanded-metal screen
Woven or expanded metal used in wall build-ups, vents and window screens; attenuation depends on aperture size relative to wavelength, so a mesh that works at 900 MHz can leak badly at 5 GHz.
Shielding & remediation
- Shielding attenuation
Decibels of field reduction provided by a material. Every 10 dB is a factor of 10 in power density: 30 dB removes 99.9%, 10 dB removes 90%.
Quantities & units
- Shielding verification
How to prove a shielding measure worked: identical instrument, position and source conditions before and after, reported in dB as well as in absolute units.