WOREMOR WM-HG10 stainless steel gauze
Coarser 1.0 mm stainless steel gauze declared at 40 dB single layer and 55 dB two layers, with 70% open area for use where light and air have to pass, and a square resistance of 0.1 Ω.
Last verified 12 August 2026.
Also searched as: WM-HG10
- Manufacturer
- WOREMOR
- Model
- WM-HG10
- Material class
- Metal mesh and expanded-metal screen
- Fields addressed
- radiofrequency, elf electric
- Grounding required
- Yes — ungrounded installation can make things worse
- Thickness
- 0.32 mm
- Surface resistance
- 0.1 Ω square resistance
Declared attenuation
Each figure is the manufacturer's declaration for the frequency and the layer or coat count named next to it. The percentage is computed from the dB value, not quoted separately.
- 1 GHz, single layer, flat sample
- 40 dB — removes 99.990% of the incident power density (1 part in 10,000 gets through)
- 1 GHz, two layers
- 55 dB — removes 100.000% of the incident power density (1 part in 316,228 gets through)
Test method
Manufacturer-declared at 1 GHz, measured to ASTM D4935-10 or IEEE Std 299-2006, with a screening report per material. Fire classification A1 to DIN 4102:1994.
Construction
Woven V4A stainless steel, 1.0 mm mesh width, 0.16 mm wire, 70% open area, 260 g/m², 90 cm wide.
Typical application
- Interior and exterior use under plaster
- Roof areas and drywall
- Insect screens over openable windows
What the figure does not cover
- 15 dB below the finer WM-HG03 at the same frequency: the larger aperture is the cost of the 70% open area
- Two-layer figures require both layers bonded and offset; simply laying a second layer loosely does not reproduce the declared 55 dB
- Requires grounding for low-frequency electric fields and correct bonding because the material is highly conductive
- The number is a flat-sample laboratory value, not a prediction of what a meter will read in a finished room
What these figures are
Every attenuation value on this page is the manufacturer's own declaration for a flat sample in a test fixture, reproduced so that products can be compared on the same terms. It is not a regulatory limit, not an independent test, and not a prediction of what a meter will read after installation — an installed shield is set by its weakest path, so the only figure that describes a room is a before-and-after measurement of that room.
Where to buy
EMR Shielding Solutions is a related company of WebKMS, which publishes EMFBase, and sells this product. The link is a stockist listing only: every figure on this page comes from the manufacturer's own documentation, and no specification, limitation or citation depends on it.
Related records
- Metal mesh and expanded-metal screen
Woven or expanded metal used in wall build-ups, vents and window screens; attenuation depends on aperture size relative to wavelength, so a mesh that works at 900 MHz can leak badly at 5 GHz.
Shielding & remediation
- Shielding attenuation
Decibels of field reduction provided by a material. Every 10 dB is a factor of 10 in power density: 30 dB removes 99.9%, 10 dB removes 90%.
Quantities & units
Sources
- woremor-wm-hg10 WOREMOR WM-HG10 stainless steel gauze — technical data — WOREMOR. manufacturer, link checked 2026-08-12.