Plug-in line filter (dirty-electricity filter)
A capacitive filter that shunts high-frequency harmonics on a circuit; effects are circuit-specific, can shift harmonics rather than remove them, and can raise magnetic fields near the filter itself.
Provisional record — listed for completeness, excluded from the search index and sitemap until every value carries a primary citation. Last verified 12 August 2026.
Also searched as: dirty electricity filter, Greenwave filter, Stetzerizer filter
- Form
- filter
- Targets
- dirty electricity
- Grounding required
- No
Failure modes
- Filters draw current, which raises the local magnetic field around the socket they occupy
- Can move harmonic energy to a different frequency band instead of removing it, improving one index while worsening another
- No recognised exposure unit to verify against; the common proprietary index is not an exposure metric
- Fixing the source (dimmer, driver, inverter) is cheaper and permanent
Related records
- Dimmer switch and phase-cutting controls
Phase-cutting dimmers chop the mains waveform and inject harmonics from a few kilohertz up to about 1 MHz onto the building wiring — the classic source of what practitioners call dirty electricity.
Sources & emitters
- Dirty-electricity (line harmonics) meter
Plugs into a socket and reports high-frequency harmonic content riding on the mains, the quantity used to judge dimmers, LED drivers, inverters and switch-mode supplies.
Instruments
Sources
- sbm-2024 Building Biology Evaluation Guidelines for Sleeping Areas (SBM-2024) — Institut für Baubiologie + Nachhaltigkeit (IBN), 2024. ngo, link checked 2026-08-12.