Carbon or nickel shielding paint
A conductive coating applied to walls and ceilings, quoted at 30–40 dB in the cellular bands; it must be bonded to a grounded conductive strip to also control low-frequency electric fields.
paintradiofrequencyelf electric
Last verified 12 August 2026.
Also searched as: EMF paint, shielding primer, carbon paint, Y-Shield
- Form
- paint
- Targets
- radiofrequency, elf electric
- Grounding required
- Yes — ungrounded installation can make things worse
- Datasheet attenuation
- 30–40 dBroughly 900 MHz – 6 GHz, two coats, datasheet valuessources: sbm-2024
Failure modes
- Ungrounded conductive paint can raise the AC electric field in the room by acting as a floating conductor
- Windows, doors and service penetrations bypass the coating entirely — the wall is rarely the dominant path
- Coating one wall while the signal arrives through the window produces no measurable improvement
- Overpainting with metallic or foil-backed products changes the result unpredictably
Related records
- RF-attenuating window film
A metallised film bonded to glazing, typically quoted at 20–35 dB, and usually the highest-value single intervention because glass is the dominant entry path for outdoor RF.
Shielding & remediation
- Shielding verification
How to prove a shielding measure worked: identical instrument, position and source conditions before and after, reported in dB as well as in absolute units.
Measurement protocols
Sources
- sbm-2024 Building Biology Evaluation Guidelines for Sleeping Areas (SBM-2024) — Institut für Baubiologie + Nachhaltigkeit (IBN), 2024. ngo, link checked 2026-08-12.