Bedroom wiring AC electric field
Live conductors in walls and in lamp flex create a power-frequency electric field that couples to the body whether or not any current flows; building biology grades below 1 V/m with ground reference as 'no anomaly'.
Last verified 12 August 2026.
Also searched as: body voltage, AC electric field bedroom
- Category
- elf electric
- Emission bands
- Power frequency and harmonics
- Environments
- home
- Duty cycle
- Continuous — the field exists whenever the circuit is energised, even with everything switched off.
Field strength by distance
- 30 cm — electric field strength
- 1–50 V/mMeasured range — SBM-2024 bands with ground reference: <1 V/m no anomaly, 1–5 weak, 5–50 strong, >50 extreme. Without ground reference the bands are <0.3 / 0.3–1.5 / 1.5–10 / >10 V/m.sources: sbm-2024
- 30 cm — body voltage
- 10–1,000 mVMeasured range — SBM-2024 body-voltage bands with ground reference: <10 mV no anomaly, 10–100 weak, 100–1000 strong, >1000 extreme. Readings depend entirely on the grounding method used, so protocol must be identical to compare.sources: sbm-2024
Mitigations, most effective first
- Unplug bedside lamps and chargers at the socket, not just at the switch.
- Removes the nearest energised conductor, usually the largest single contribution at the pillow.
- Fit a demand switch (Netzfreischalter) on the bedroom lighting circuit.
- De-energises the circuit when no load is drawing, eliminating the field for the whole night.
- Use shielded cable or grounded shielding paint on the wall behind the bed head where rewiring is impractical.
- Grounded conductive surfaces block power-frequency electric fields effectively — unlike magnetic fields.
Measure with
- AC electric field meter
- Body-voltage measurement kit
Related records
- Building Biology SBM-2024 AC electric field bands
Sleeping-area grades with ground reference: below 1 V/m no anomaly, 1–5 weak, 5–50 strong, above 50 V/m extreme; body voltage below 10 mV is 'no anomaly'.
Exposure limits
- Body-voltage measurement
The building-biology method for grading a sleeping area's AC electric field: a high-impedance millivoltmeter, a hand electrode, and a documented ground reference.
Measurement protocols
- Body voltage
Millivolts induced on a person by nearby power-frequency electric fields, measured against a ground reference; the metric building biologists use to judge bedroom wiring.
Quantities & units