Body-voltage measurement
The building-biology method for grading a sleeping area's AC electric field: a high-impedance millivoltmeter, a hand electrode, and a documented ground reference.
Last verified 12 August 2026.
Also searched as: how to measure body voltage
- Quantity measured
- body voltage
Goal
Quantify capacitive coupling from building wiring to a person at the sleeping position, and identify which circuits and devices contribute.
Equipment
- Body-voltage measurement kit
- AC electric field meter
Procedure
- Establish and document the ground reference: protective earth at a socket, or a dedicated ground rod. Readings are not comparable across different references.
- Lie or sit in the normal sleeping position, holding the hand electrode, with the meter on AC millivolts.
- Record the baseline with the room in its normal night-time state.
- Unplug items one at a time — bedside lamp, charger, extension lead — recording the reading after each.
- Switch off individual circuits at the consumer unit, recording after each, to attribute the remainder to specific circuits.
- Repeat after any mitigation (demand switch, shielded cable, shielding paint) using the identical reference and posture.
- Report the ground reference, posture and circuit states alongside every number.
Pitfalls
- Comparing a reading against someone else's number when the ground reference differs
- Assuming a low body voltage means low magnetic field exposure — the two are independent
- Grounding a shielding surface incorrectly and creating a larger field than before
- Working inside a consumer unit without a qualified electrician
Interpret results against
- Building Biology SBM-2024 AC electric field bands
Related records
- Bedroom wiring AC electric field
Live conductors in walls and in lamp flex create a power-frequency electric field that couples to the body whether or not any current flows; building biology grades below 1 V/m with ground reference as 'no anomaly'.
Sources & emitters
- Demand switch (Netzfreischalter)
A relay in the consumer unit that de-energises a circuit when no load is drawing current and re-energises it when a switch is thrown, eliminating the bedroom AC electric field overnight.
Shielding & remediation
Sources
- sbm-2024 Building Biology Evaluation Guidelines for Sleeping Areas (SBM-2024) — Institut für Baubiologie + Nachhaltigkeit (IBN), 2024. ngo, link checked 2026-08-12.
Same record, other formats