EMFBase

Brussels cumulative limit, publicly accessible outdoor areas

f/1597.28 W/m² summed over all fixed transmitters — 0.5635 W/m² (14.57 V/m) at 900 MHz, about a tenth of the EU reference level in power terms.

Regulatorygeneral public400–2000 MHz, outdoors

Last verified 12 August 2026.

Limit value
250,400–1,252,000 µW/m²Regulatory value — legally enforceable — The range is the band edges: 0.2504 W/m² at 400 MHz to 1.2520 W/m² at 2000 MHz. The ordinance itself gives 0.5635 W/m² = 14.57 V/m at 900 MHz as its worked example, and sets 0.2497 W/m² for 0.1–400 MHz and 1.2539 W/m² for 2–300 GHz. The limit applies at no moment to be exceeded, not as a time average.sources: brussels-ordinance-2007
Quantity
power density
Frequency band
400–2000 MHz, outdoors
Population
general public
Set by
Brussels-Capital non-ionising radiation ordinance (Ordinance of 1 March 2007, as amended 2 March 2023, in force 1 May 2023)
Kind
Regulatory — legally enforceable
Frequency-dependent formula
f/1597.28 W/m² (f in MHz)

Related records

Sources

  1. brussels-ordinance-2007 Ordonnance du 1er mars 2007 relative à la protection de l'environnement contre les éventuels effets nocifs et nuisances provoqués par les radiations non ionisantes (texte coordonné, art. 3) Région de Bruxelles-Capitale, Moniteur belge / Justel, 2007. regulation, link checked 2026-08-12.

Same record, other formats