ICNIRP 2020 general public reference level, 400 MHz–2 GHz
Frequency-scaled reference level f/200 W/m², giving 4.5 W/m² at 900 MHz and 9 W/m² at 1800 MHz.
Guidelinegeneral public400–2000 MHz
Last verified 12 August 2026.
- Limit value
- 2,000,000–1 × 10^7 µW/m²Guideline value — scientific recommendation — 2 W/m² at 400 MHz rising to 10 W/m² at 2000 MHz; 4,500,000 µW/m² at 900 MHz.sources: icnirp-2020
- Quantity
- power density
- Frequency band
- 400–2000 MHz
- Population
- general public
- Set by
- ICNIRP 2020 RF guidelines (100 kHz–300 GHz) (2020)
- Kind
- Guideline — scientific recommendation
- Averaging time
- 30 minutesA measurement must use the same averaging before it can be compared with this value.
- Frequency-dependent formula
- f/200 W/m² (f in MHz)
Sources
- icnirp-2020 Guidelines for Limiting Exposure to Electromagnetic Fields (100 kHz to 300 GHz) — International Commission on Non-Ionizing Radiation Protection, 2020. guideline, link checked 2026-08-12.
- eu-1999-519 Council Recommendation 1999/519/EC on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) — Council of the European Union, 1999. regulation, link checked 2026-08-12.
Same record, other formats