WOREMOR RF-IE50 PLUS shielding paint
Maximum-attenuation version of RF-IE50, declared at 40 dB one layer, 48 dB two layers and 54 dB three layers at 1 GHz, and 44/66/86 dB at 40 GHz, with the manufacturer noting reduced hardness and abrasion resistance as the trade-off.
Last verified 12 August 2026.
Also searched as: RF-IE50 PLUS, WOREMOR PLUS paint
- Manufacturer
- WOREMOR
- Model
- RF-IE50 PLUS
- Material class
- Carbon or nickel shielding paint
- Fields addressed
- radiofrequency, elf electric
- Grounding required
- Yes — ungrounded installation can make things worse
- Coverage
- 5 litres covers roughly 37 m² (400 sq ft) as a single layer.
Declared attenuation
Each figure is the manufacturer's declaration for the frequency and the layer or coat count named next to it. The percentage is computed from the dB value, not quoted separately.
- 1 GHz, one layer
- 40 dB — removes 99.990% of the incident power density (1 part in 10,000 gets through)
- 1 GHz, two layers
- 48 dB — removes 99.998% of the incident power density (1 part in 63,096 gets through)
- 1 GHz, three layers
- 54 dB — removes 100.000% of the incident power density (1 part in 251,189 gets through)
- 40 GHz, one layer
- 44 dB — removes 99.996% of the incident power density (1 part in 25,119 gets through)
- 40 GHz, two layers
- 66 dB — removes 100.000% of the incident power density (1 part in 3,981,072 gets through)
- 40 GHz, three layers
- 86 dB — removes 100.000% of the incident power density (1 part in 3.98 × 10^8 gets through)
Test method
Manufacturer-declared, measured in WOREMOR's own EMC laboratory to 40 GHz; declared values are quoted at 1 GHz and 40 GHz for one to three layers.
Construction
Water-based acrylic dispersion with natural graphite and carbon black, solvent-free and plasticiser-free.
Typical application
- Interior and exterior walls, ceilings and floors
- Rooms where the target level needs every available dB
What the figure does not cover
- The manufacturer states limitations in hardness and abrasion resistance, so it needs a protective top coat in trafficked areas
- Must be grounded — interior via a grounding strap and plate, exterior via the fibre additive and ground plate the manufacturer specifies
- Layer counts are not interchangeable: the 54 dB figure requires three continuous layers, and a thin third layer does not deliver it
- The declared figures are flat-sample laboratory values and exclude windows, seams and penetrations, which normally set the installed result
What these figures are
Every attenuation value on this page is the manufacturer's own declaration for a flat sample in a test fixture, reproduced so that products can be compared on the same terms. It is not a regulatory limit, not an independent test, and not a prediction of what a meter will read after installation — an installed shield is set by its weakest path, so the only figure that describes a room is a before-and-after measurement of that room.
Where to buy
EMR Shielding Solutions is a related company of WebKMS, which publishes EMFBase, and sells this product. The link is a stockist listing only: every figure on this page comes from the manufacturer's own documentation, and no specification, limitation or citation depends on it.
Related records
- Carbon or nickel shielding paint
A conductive coating applied to walls and ceilings, quoted at 30–40 dB in the cellular bands; it must be bonded to a grounded conductive strip to also control low-frequency electric fields.
Shielding & remediation
- Shielding attenuation
Decibels of field reduction provided by a material. Every 10 dB is a factor of 10 in power density: 30 dB removes 99.9%, 10 dB removes 90%.
Quantities & units
Sources
- woremor-rf-ie50-plus WOREMOR RF-IE50 PLUS shielding paint — technical data — WOREMOR. manufacturer, link checked 2026-08-12.
Same record, other formats