EMFBase

Flanders VLAREM transmitting antenna norms

Flanders caps the cumulative field from all fixed transmitters at 0.686 √f V/m — 20.6 V/m at 900 MHz, 30.7 V/m from 2 GHz up — with a separate per-operator condition in VLAREM chapter 6.10.

Legally enforceableBE-VLGVLAREM II chapters 2.14 and 6.10, most recently amended by the decision of 10 June 2022, in force 31 July 2022

Last verified 12 August 2026.

Also searched as: VLAREM 2.14, VLAREM 6.10, Flanders antenna norm, Flemish EMF limits

Organization
Flemish Government, Department of Environment (Belgium)
Edition
VLAREM II chapters 2.14 and 6.10, most recently amended by the decision of 10 June 2022, in force 31 July 2022
Jurisdiction
BE-VLG
Frequency range
100 kHz – 300 GHz
Status of values
Legally enforceable in at least one jurisdiction

Scope

Environmental quality norms (chapter 2.14) bound the sum of all fixed transmitting antennas — mobile, radio, TV, radar, amateur, emergency-service and defence — while environmental conditions (chapter 6.10) bound each operator's own contribution at places of stay. Mobile handsets are excluded and covered by federal product norms instead. Since the 2022 amendment the norms span 100 kHz to 300 GHz.

Sources

  1. flanders-vlarem-antennas Normen zendantennes — VLAREM hoofdstuk 2.14 (milieukwaliteitsnormen) en hoofdstuk 6.10, met grenswaardentabel Departement Omgeving, Vlaamse overheid (Flanders, Belgium). regulation, link checked 2026-08-12.
  2. flanders-vlarem-text Besluit van de Vlaamse Regering van 19 november 2010 — VLAREM titel II, art. 2.14.2.1 en 6.9.2.1: grenswaarden elektrische veldsterkte voor zendantennes (Eiref = 0,686 √f V/m van 400 tot 2000 MHz) Vlaamse overheid, Belgisch Staatsblad (via etaamb), 2010. regulation, link checked 2026-08-12.