Korea public magnetic limit at 60 Hz
83.3 µT (833 mG) at Korea's 60 Hz mains frequency — the ICNIRP 1998 reference level, which Korea kept rather than moving to the 200 µT figure of the 2010 revision.
Regulatorygeneral public60 Hz
Last verified 12 August 2026.
- Limit value
- 83.3 µTRegulatory value — legally enforceable — The general-public table gives B = 5/f µT with f in kHz for 25 Hz–0.8 kHz, which is 83.3 µT at 60 Hz; the RRA states the Korean power-frequency figure as 833 mG. Korea separately notes that 4 mG values quoted for Switzerland, the Netherlands and Denmark are installation or quality targets, not human-protection limits.sources: korea-emf-protection-standard
- Quantity
- magnetic flux density
- Frequency band
- 60 Hz
- Population
- general public
- Set by
- Korea EMF human protection standard (전자파 인체보호기준) (MSIT Notice No. 2019-4 under Radio Waves Act art. 47-2)
- Kind
- Regulatory — legally enforceable
- Frequency-dependent formula
- 5/f µT for 25 Hz–0.8 kHz (f in kHz)
Related records
- ICNIRP 2010 general public magnetic field reference level at 50/60 Hz
200 µT (2000 mG) for the public and 1000 µT occupational — five orders of magnitude above typical household background.
Exposure limits
- Japan power-frequency magnetic limit for electrical facilities
200 µT (2000 mG) at commercial frequency in the space a person would occupy near transformers, switchgear and power lines, binding since 1 October 2011.
Exposure limits
Sources
- korea-emf-protection-standard 전자파 인체보호기준 — 전자파강도 기준표 (Human protection standard for electromagnetic waves: field-strength tables) — 국립전파연구원 (National Radio Research Agency, Ministry of Science and ICT, Republic of Korea). regulation, link checked 2026-08-12.