Poland residential-zoning magnetic limit at 50 Hz
60 A/m on land zoned for housing, which is 75 µT (750 mG) — slightly below the EU's 100 µT reference level.
Regulatorygeneral public50 Hz
Last verified 12 August 2026.
- Limit value
- 75.4 µTRegulatory value — legally enforceable — The regulation states the magnetic component as H = 60 A/m; in air B = µ₀H = 4π × 10⁻⁷ × 60 = 75.4 µT. The same 60 A/m value appears in Table 2 for places accessible to the public from 0.5 to 50 Hz.sources: poland-mz-2019-2448
- Quantity
- magnetic flux density
- Frequency band
- 50 Hz
- Population
- general public
- Set by
- Poland environmental EMF limits (Dz.U. 2019 poz. 2448) (Regulation of 17 December 2019, in force 1 January 2020)
- Kind
- Regulatory — legally enforceable
Related records
- ICNIRP 2010 general public magnetic field reference level at 50/60 Hz
200 µT (2000 mG) for the public and 1000 µT occupational — five orders of magnitude above typical household background.
Exposure limits
- Poland residential-zoning electric limit at 50 Hz
1000 V/m on land zoned for housing — five times stricter than the 5000 V/m EU/ICNIRP reference level, and a separate stricter tier from the 10,000 V/m that applies in other publicly accessible places.
Exposure limits
Sources
- poland-mz-2019-2448 Rozporządzenie Ministra Zdrowia z dnia 17 grudnia 2019 r. w sprawie dopuszczalnych poziomów pól elektromagnetycznych w środowisku (Dz.U. 2019 poz. 2448) — Minister Zdrowia (Poland), Dziennik Ustaw, 2019. regulation, link checked 2026-08-12.