EMFBase

Flanders cumulative antenna limit

0.686 √f V/m for all fixed transmitters combined — 13.7 V/m below 400 MHz, 20.6 V/m at 900 MHz, 29.1 V/m at 1800 MHz and 30.7 V/m from 2 GHz up.

Regulatorygeneral public400–2000 MHz

Last verified 12 August 2026.

Limit value
13.7–30.7 V/mRegulatory value — legally enforceable — VLAREM II environmental quality norm: 13.7 V/m from 10 to 400 MHz, 0.686 √f V/m from 400 to 2000 MHz and 30.7 V/m above 2000 MHz, as a spatially averaged level. The Flemish Government's published table gives 18.1 V/m at 700 MHz, 19.4 V/m at 800 MHz, 20.6 V/m at 900 MHz and 29.1 V/m at 1800 MHz, currently averaged over 30 minutes. Chapter 6.10 caps each operator's own contribution separately, so a site shared by several operators is bound by both.sources: flanders-vlarem-antennas, flanders-vlarem-text
Quantity
electric field strength
Frequency band
400–2000 MHz
Population
general public
Set by
Flanders VLAREM transmitting antenna norms (VLAREM II chapters 2.14 and 6.10, most recently amended by the decision of 10 June 2022, in force 31 July 2022)
Kind
Regulatory — legally enforceable
Frequency-dependent formula
0.686 √f V/m (f in MHz)

Related records

Sources

  1. flanders-vlarem-antennas Normen zendantennes — VLAREM hoofdstuk 2.14 (milieukwaliteitsnormen) en hoofdstuk 6.10, met grenswaardentabel Departement Omgeving, Vlaamse overheid (Flanders, Belgium). regulation, link checked 2026-08-12.
  2. flanders-vlarem-text Besluit van de Vlaamse Regering van 19 november 2010 — VLAREM titel II, art. 2.14.2.1 en 6.9.2.1: grenswaarden elektrische veldsterkte voor zendantennes (Eiref = 0,686 √f V/m van 400 tot 2000 MHz) Vlaamse overheid, Belgisch Staatsblad (via etaamb), 2010. regulation, link checked 2026-08-12.

Same record, other formats