EMFBase

Korea public limit, 400–2000 MHz

f/200 W/m² (f in MHz) — 4.5 W/m² at 900 MHz and 9 W/m² at 1800 MHz, with E = 1.375 √f V/m.

Regulatorygeneral public400–2000 MHz

Last verified 12 August 2026.

Limit value
2,000,000–1 × 10^7 µW/m²Regulatory value — legally enforceable — The range is the band edges: 2 W/m² at 400 MHz to 10 W/m² at 2000 MHz. At 900 MHz the limit is 4.5 W/m², equivalently 41.25 V/m.sources: korea-emf-protection-standard
Quantity
power density
Frequency band
400–2000 MHz
Population
general public
Set by
Korea EMF human protection standard (전자파 인체보호기준) (MSIT Notice No. 2019-4 under Radio Waves Act art. 47-2)
Kind
Regulatory — legally enforceable
Averaging time
6 minutesA measurement must use the same averaging before it can be compared with this value.
Frequency-dependent formula
f/200 W/m², E = 1.375 √f V/m (f in MHz)

Related records

Sources

  1. korea-emf-protection-standard 전자파 인체보호기준 — 전자파강도 기준표 (Human protection standard for electromagnetic waves: field-strength tables) 국립전파연구원 (National Radio Research Agency, Ministry of Science and ICT, Republic of Korea). regulation, link checked 2026-08-12.

Same record, other formats