EMFBase

Distance and exposure estimator

S = EIRP / (4πd²) gives the main-beam free-space upper bound. Real exposure is almost always lower — and this formula is simply invalid within about a wavelength of the antenna, which is where a handset against the head sits.

31,831 µW/m² at 50 m

= 0.0318 W/m² = 3.46 V/m (far-field equivalent)

S = EIRP / (4πd²)

Compared with published values

Regulatory values are enforceable, guidelines are recommendations, and precautionary values are proposed by professional or advocacy bodies and are not law anywhere. A number can sit far below the first and far above the third at the same time.

ValueKindLimitEstimate as % of itFree-space distance to reach it
FCC occupational MPE, 1.5–100 GHzFCC Maximum Permissible Exposure (47 CFR 1.1310) · occupational · 1500–100,000 MHzregulatory50000000 µW/m²0.0637%1.26 m
FCC general population MPE, 1.5–100 GHzFCC Maximum Permissible Exposure (47 CFR 1.1310) · general public · 1500–100,000 MHzregulatory10000000 µW/m²0.318%2.82 m
UK enforceable general-public limit, 2–300 GHzUK Ofcom EMF licence condition · general public · 2–300 GHzregulatory10000000 µW/m²0.318%2.82 m
Australian general-public limit, 2–300 GHzARPANSA RPS S-1 (2021) · general public · 2–300 GHzregulatory10000000 µW/m²0.318%2.82 m
Brazil public limit, 2–300 GHzBrazil Anatel RF exposure limits (Ato 17865/2023) · general public · 2–300 GHzregulatory10000000 µW/m²0.318%2.82 m
FCC general population MPE, 300–1500 MHzFCC Maximum Permissible Exposure (47 CFR 1.1310) · general public · 300–1500 MHzregulatory2000000 µW/m²1.59%6.31 m
Japan general-environment limit, 300 MHz–1.5 GHzJapan Radio Radiation Protection Guidelines (電波防護指針) · general public · 300 MHz–1.5 GHzregulatory2000000 µW/m²1.59%6.31 m
Korea public limit, 400–2000 MHzKorea EMF human protection standard (전자파 인체보호기준) · general public · 400–2000 MHzregulatory2000000 µW/m²1.59%6.31 m
Poland public limit, 400–2000 MHzPoland environmental EMF limits (Dz.U. 2019 poz. 2448) · general public · 400–2000 MHzregulatory2000000 µW/m²1.59%6.31 m
Brazil public limit, 400–2000 MHzBrazil Anatel RF exposure limits (Ato 17865/2023) · general public · 400–2000 MHzregulatory2000000 µW/m²1.59%6.31 m
India base-station limit, 2–300 GHzIndia DoT base-station EMF norms (1/10th of ICNIRP) · general public · 2–300 GHzregulatory1000000 µW/m²3.18%8.92 m
China public limit, 30–3000 MHzChina GB 8702-2014 electromagnetic environment control limits · general public · 30–3000 MHzregulatory400000 µW/m²7.96%14.1 m
China public limit, 3–15 GHzChina GB 8702-2014 electromagnetic environment control limits · general public · 3000–15,000 MHzregulatory400000 µW/m²7.96%14.1 m
Brussels cumulative limit, publicly accessible outdoor areasBrussels-Capital non-ionising radiation ordinance · general public · 400–2000 MHz, outdoorsregulatory250400 µW/m²12.7%17.8 m
India base-station limit, 400–2000 MHzIndia DoT base-station EMF norms (1/10th of ICNIRP) · general public · 400–2000 MHzregulatory200000 µW/m²15.9%19.9 m
Russia public limit, 300 MHz–300 GHzRussia SanPiN public RF limits · general public · 0.3–300 GHzregulatory100000 µW/m²31.8%28.2 m
Brussels cumulative limit, publicly accessible indoor areasBrussels-Capital non-ionising radiation ordinance · general public · 400–2000 MHz, indoorsregulatory99700 µW/m²31.9%28.3 m
ICNIRP 2020 general public reference level, 2–300 GHzICNIRP 2020 RF guidelines (100 kHz–300 GHz) · general public · 2–300 GHzguideline10000000 µW/m²0.318%2.82 m
Safety Code 6 uncontrolled reference level, 6–15 GHzHealth Canada Safety Code 6 (2015) · general public · 6000–15,000 MHzguideline10000000 µW/m²0.318%2.82 m
ICNIRP 2020 general public reference level, 400 MHz–2 GHzICNIRP 2020 RF guidelines (100 kHz–300 GHz) · general public · 400–2000 MHzguideline2000000 µW/m²1.59%6.31 m
Safety Code 6 uncontrolled reference level, 300–6000 MHzHealth Canada Safety Code 6 (2015) · general public · 300–6000 MHzguideline1290000 µW/m²2.47%7.85 m
Building Biology SBM-2024 RF band: extreme anomalyBuilding Biology SBM-2024 evaluation guidelines · sensitive · per single RF source, peakprecautionary1000 µW/m²3,183%282 m
EUROPAEM 2016 night-time target value for WLAN and similar pulsed sourcesEUROPAEM EMF Guideline 2016 · sensitive · pulsed digital servicesprecautionary10 µW/m²318,310%2,821 m

JSON: /api/safe-distance